                                        PSA Hydrogen Gas Generation Plants
                                     
                                 | 
                             
                            
                                
                                    
                                        
                                            
                                                
                                                                                                
                                                    Technical
                                                        Specifications
                                                    
                                                        
                                                            | 
                                                                 
                                                                    Flow rate: 
                                                             | 
                                                            
                                                                 
                                                                    5 Nm3/h
                                                                        to 75 Nm3/h 
                                                             | 
                                                         
                                                        
                                                            | 
                                                                 
                                                                    H2 Purity: 
                                                             | 
                                                            
                                                                 
                                                                    95% to 97%
                                                                        (based on customer's requirements) 
                                                             | 
                                                         
                                                        
                                                            | 
                                                                 
                                                                    Dew point: 
                                                             | 
                                                            
                                                                 
                                                                    Up to -90°C 
                                                             | 
                                                         
                                                        
                                                            | 
                                                                 
                                                                    Pressure:    
                                                                        
                                                                 
                                                             | 
                                                            
                                                                 
                                                                    3.5 kg/cm2
                                                                        g to 4 
                                                                            kg/cm2 
                                                             | 
                                                         
                                                     
                                                 
                                                
                                                
                                                    Features and Benefits :
                                                     
                                                        - Without booster compressor 4 Kg/cm2 Further Purification of Dissociated Ammonia
                                                            to Pure Hydrogen.
 
                                                        - Use special grade of Zeolites from CECA, France / Zeochem, Switzerland to purify
                                                            hydrogen nitrogen mixtures to pure hydrogen.
 
                                                        - Hydrogen Levels of 95-98% achieved on continuous basis.
 
                                                        - Cost Effective and Efficient method of generating ob-line hydrogen,
 
                                                        - Widely used in Brazing and other Metallurgical Furnace applications.
 
                                                        - Nitrogen being inert gas, the mixture of H2-N2 95-5% is used as pure hydrogen.
 
                                                        Storage of such hydrogen very effective for peak requirements
                                                     
                                                                                                 
                                             | 
                                         
                                     
                                 | 
                             
                            
                                | 
                                 | 
                             
                         
                     | 
                    
                        
                     |